Dash -4 hydraulic fittings: thread, wrench and torque

JIC uses 7/16-20 UNF; SAE ORB uses 7/16-20 UNF; ORFS uses 9/16-18 UNF. Check the seal as well as the thread before ordering.

Last reviewed November 21, 2026. Sources are listed at the bottom of the page. Report a mistake on this page

Updated : what changed

Added the -14, -16, -20 and -24 sizes, and the nut wrench size for JIC and ORFS at each dash size.

Compare the three standards

Compare the sealing surface as well as the thread.

-4 thread and seal by standard. A shared thread does not mean the fittings connect.
StandardThreadThread OD (nominal)SealNut wrench size (Parker)
JIC7/16-20 UNF0.438 in (11.1 mm)Metal-to-metal, 37-degree flare cone9/16 in
SAE ORB7/16-20 UNF0.438 in (11.1 mm)O-ring compressed into the port's tapered seatNo tube nut; body hex varies by part
ORFS9/16-18 UNF0.563 in (14.3 mm)O-ring face seal (elastomeric)11/16 in

OD means outside diameter. The pitch is part of the thread designation. Measure the thread and inspect the sealing surface; a shared number does not make two standards interchangeable.

-4 assembly torque (Parker)

Parker published assembly torque at -4, steel fittings
StandardTorqueParker table
JIC155 in-lb (13 ft-lb), +10% -0Parker Table R22
SAE ORB260 in-lb (29 N·m) (light duty, non-adjustable port)Parker Table R1
ORFS220 in-lb (18 ft-lb), +10% -0Parker Table R14

Parker publishes these at +10% -0 for steel fittings; the SAE ORB port values assume plated steel fittings in steel ports. Parker's material and lubrication conditions, flats-from-wrench-resistance values, and adjustable and heavy-duty port values are in the hydraulic fitting torque chart. Other makers publish different values for the same size.

What -4 means here

In these tube-fitting charts, -4 corresponds to 1/4" tube size. That is not the outside diameter of its thread. Each standard chart linked in the table shows the full range and its naming convention.

Which connection is in your hand?

If you cannot distinguish the seat or O-ring location, use the Thread Identifier before selecting a replacement. For a different dash number, return to the dash-size comparison. NPT uses nominal pipe sizes, not dash numbers: check a pipe-size marking against the NPT chart.

Source and scope

Dash number = tube OD in sixteenths of an inch (-8 = 1/2 in). The threads match the JIC, SAE ORB and ORFS charts on this site and were checked against Swagelok MS-13-77, page 29; its end-connection drawings explain the different seals. Nominal thread diameter is calculated from the thread designation. It is not a measured acceptance range.

Wrench sizes are the tube nut hex across the flats from Parker Catalog 4300 PDF Version 13 (8/2026): Triple-Lok 37-degree Flared Tube Ends (PDF page 60) and Seal-Lok O-Ring Face Seal Tube Ends (PDF page 24). They apply to Parker nuts; other makers and fitting bodies can differ.

Swagelok lists these rows by nominal size in inches, not by dash number; the dash numbers come from that sixteenths rule.

Reference data only. Verify thread dimensions with a thread identification gauge before making connections. Working with pressurized hydraulic systems involves serious injury risks including high-pressure injection, burns, and crushing hazards.

Before loosening any fitting: shut the machine down, relieve all system pressure (including accumulators and pressure trapped in cylinders), and lower or block any raised load. Never feel for a leak with your hand; use a piece of cardboard. A pinhole jet of hydraulic fluid can inject under the skin, and an injection injury needs emergency medical care even if it looks minor.